F f is measured as the curvature of the floor over a 2 foot interval.
Ff 35 floor flatness.
Concrete strengths rebar average rebar weights welded wire mesh pan slabs slab flatness and f numbers.
Actual overall f numbers shall be calculated using.
They describe a concrete slab s flatness ff and.
Flat 35 25 very flat 45 35.
F numbers provide architects and contractors a method of determining the flatness and levelness of a concrete floor slab.
Floor flatness variation from surface plane bumpiness f l floor levelness variation from horizontal plane pitch.
To quantify floor flatness using f numbers you begin by measuring the elevation differences d between points on the floor that are 1 foot apart along a straight line.
The f f value is primarily a result of how good the finisher was at working the.
What does a specification for a floor flatness of 1 8 inch in 10 feet equal in f numbers.
Although there are no direct equivalents between f numbers and straightedge tolerances aci 302 construction of concrete floors and slabs gives the following table of approximate values.
However it also advises that the selection of the proper ff fl tolerances for a new project is best made by measurement of a similar satisfactory existing floor.
F f 25 f l 20 moderately flat.
A self propelled laser guided screed can routinely create f l numbers of about 35 and higher.
A self propelled laser guided screed can routinely create fl numbers of about 35 and higher.
Minimum subfloor flatness using astm e1155 ff sof f or a 10 3m.
Concrete slab flatness slab flatness the degree of a slab s flatness is expressed by two numbers the ff and the fl together these are the f numbers they are the face floor profile numbers developed by allen face from 1978 to 1987.
It recommends that slabs to receive thin set flooring with moderate or heavy traffic have composite flatness and levelness of ff 35 fl 25.
F f this number is used to indicate the flatness of a random traffic floor.
F f and f l tolerances shall be tested in accordance with astm e 1155.
Ff25 fl20 moderately flat ff35.
F l specified overall value 25 minimum local value 18 c.
Ff fl numbers have the following floor flatness classifications.
Take a grid of 2 foot intervals over the entire floor and put the values through an equation and you get the f f value as an indication of the waviness of the floor.
F f specified overall value 35 minimum local value 24 floor levelness number.